The Immediate Effect of the Variation of Anteroposterior Laterotrusive Contacts on the Elevator EMG Activity
1993
ABSTRACTA unilateral maxillary splint divided into three occlusal blocks was built for eight healthy young adults. The three blocks allowed the anteroposterior location of the laterotrusive contacts to vary and to distribute the occlusal force over equivalent periodontal surfaces. The ipsilateral masseteric and temporalis electromyogram (EMG) activities were recorded with surface electrodes during maximal voluntary clenching. The elevator EMG activity with the anterior occlusal block in place was significantly lower than with the intermediate or posterior blocks. The reduction for both elevators with the intermediate block in place did not show a significant variation in comparison to the posterior block or the three blocks inserted. The elevator activity with the three occlusal blocks did not differ from that recorded with the posterior block alone. Neurophysiology and biomechanics explanations are given related to this laterotrusive elevator muscular behavior.