Examination of shipping packages 9975-01641, 9975-01692, 9975-03373, 9975-02101 AND 9975-02713

2016 
SRNL has assisted in the examination of five 9975 shipping packages following storage of nuclear material in K-Area Complex (KAC). Two packages (9975-01641 and -01692) with water intrusion resulting from a roof leak were selected for detailed examination after internal fiberboard degradation (mold) was observed. 9975-01692 contained regions of saturated fiberboard and significant mold, while the second package was less degraded. A third package (9975-03373) was removed from storage for routine surveillance activities, and set aside for further examination after a musty odor was noted inside. No additional degradation was noted in 9975-03373, but the lower assembly could not be removed from the drum for detailed examination. Two additional packages (9975-02101 and -02713) identified for further examination were among a larger group selected for surveillance as part of a specific focus on high-wattage packages. These two packages displayed several non-conforming conditions, including the following: (1) the axial gap criterion was exceeded, (2) a significant concentration of moisture was found in the bottom fiberboard layers, with active mold in this area, (3) condensation and/or water stains were observed on internal components (drum, lid, air shield), and (4) both drums contained localized corrosion along the bottom lip. It is recommended that amore » new screening check be implemented for packages that are removed from storage, as well as high wattage packages remaining in storage. An initial survey for corrosion along the drum bottom lip of high wattage packages could identify potential degraded packages for future surveillance focus. In addition, after packages have been removed from storage (and unloaded), the drum bottom lip and underside should be inspected for corrosion. The presence of corrosion could signal the need to remove the lower fiberboard assembly for further inspection of the fiberboard and drum prior to recertification of the package.« less
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    0
    Citations
    NaN
    KQI
    []