Potential In-Hospital Modes of Transmission of Legionella pneumophila Demonstration Experiments for Dissemination by Showers, Humidifiers, and Rinsing of Ventilation Bag Apparatus

1986 
Abstract The mode of transmission of nosocomial legionellosis remains uncertain. Aerosolization of Legionella pneumophila by showers, humidifiers, and respiratory equipment rinsed in tap water was evaluated using plate-settling culture and air aspirator methods. All protocols simulated the actual hospital setting including use of humidifier equipment used in hospital patient rooms and water from faucets and showerheads in hospitals with nosocomial Legionnaires' disease. Protocols for humiditier and shower experiments mimicked the procedure actually used in hospitals by health care personnel. Showering failed to produce aerosols of L. pneumophila; however, portable humidifiers readily generated aerosols of L. pneumophila that disseminated throughout a two-bed patient room. Intensity of aerosolization directly correlated with the degree of L. pneumophila contamination of the tap water used to fill the humidifier. Rinsing of ventilation bag apparatus with tap water led to isolation of L. pneumophila from culture plates after the ventilation bags were squeezed. Thus, L. pneumophila could be aerosolized or directly instilled into a patient's bronchial tree following routine measures for cleaning ventilation bag apparatus with tap water. On the basis of these results, the use of humidifiers filled with tap water has been discontinued and sterile water is recommended for rinsing ventilation bag apparatus and tubing.