Test and Inverse Analysis for Temperature Control Parameters of Concrete with Cooling Pipe

2011 
Based on the genetic algorithm of inverse problem and the 3-D FEM,non-adiabatic temperature rise test of rectangle with cooling pipe based on actual project was done to identify adiabatic temperature rise,heat exchange coefficient and so on.The comparison results showed that different temperature control parameters can indicate the real thermal properties of concrete in site.The method of the combination of test and reverse analysis is simple and economical,and many temperature control parameters can be obtained simultaneously,so it has high engineering values in the future.