Validated RP-HPLC method for the simultaneous determination of amlodipine besylate, valsartan, and hydrochlorothiazide in bulk and in pharmaceutical formulation

2012 
Summary A reverse-phase high-performance liquid chromatographic (RP-HPLC) method was developed for the simultaneous estimation of amlodipine besylate (AMB), valsartan (VAL), and hydrochlorothiazide (HCT) in pharmaceutical formulation using RP-C18 column. The mobile phase (acetonitrile:methanol:50 mM phosphate buffer adjusted to pH 3 with orthophosphoric acid) was pumped at a flow rate of 1.0 mL min−1 in the ratio of 20:50:30% v/v and the eluents were monitored at 239 nm. Linearity was obtained in the concentration range of 0.5–5 μg mL−1 for AMB, 4–40 μg mL−1 for VAL, and 1–10 μg mL−1 for HCT. The method was validated as per International Conference on Harmonization (ICH) guidelines and statistically. The method was validated for accuracy and precision. For precision, the coefficient of variance (COV) was found to be 0.3794, 0.1703 and 0.0578, and for accuracy, it was found to be 0.6351, 0.7688 and 1.1305 for AMB, VAL, and HCT, respectively. The COV values for all the drugs were found to be less than 2%, i...
    • Correction