Monte Carlo simulation of the Massachusetts institute of technology research reactor

1994 
The three-dimensional continuous-energy MCNP Monte Carlo code is used to develop a versatile and accurate reactor physics model of the Massachusetts Institute of Technology research reactor II (MITR-II). The validation of the model against existing experimental data is presented. Core multiplication factors as well as fast neutron in-core flux measurements were used in the validation process. The agreement between the MCNP predictions and the experimentally determined values is very good, which indicates that the Monte Carlo model is correctly simulating the MITR-II