원보 : 새로운 생약복합제제(HPL-4)의 품질관리를 위한 분석법 개발

2014 
HPL-4 is a new herbal formulation developed for the treatment of osteoarthritis. In this study, we took HPL-4 to develop a method for simultaneous determination of nine marker compounds (protocatechuic acid, chlorogenic acid, liriodendrin, nodakenin, β-D-(3-O-sinapoyl)frucofuranosyl-α-D-(6-O-sinapoyl)glucopyranoside, quercitrin, 6-gingerol, decursin and decursinol angelate) present in the formulation. The analytes were separated by UPLC system consisting of diode array detector at 205 nm and RP-amide column, and solvent system of ACN/0.1%H3PO4. Analytical method was validated to evaluate its linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy. All standards showed good linearity (R 2 >0.99) in the rage of 0.25-400.0 μg/mL. The LOD and LOQ were within the range of 0.021-0.148 and 0.070-0.448 μg/mL, respectively. Intra- and inter-day precision was less than RSD 4.0% and the accuracy was range from 92.00-104.81% with RSD<4.2%. The results suggest that the developed UPLC method is precise, accurate and effective, and could be applied for quality control of HPL-4 formulation.