IEC 61400-1 DLC1.1과 DLC1.3에 대한 풍력터빈의 극한하중 특성

2012 
IEC 61400-1 requires design lifetime of wind turbines at least 20 years, thus wind turbine should be assured for structural safety through load assessment. DLCs have been defined with respect to the load assessment in IEC 61400-1. In addition, if the extreme design values for DLC1.3 are equal or exceed the extreme design value for DLC1.1, DLC1.1 may be omitted. To omit DLC1.1, scale factor (c) will be increased in DLC1.3. However, this particular adjustment is not specified guidelines. Thus, this study was conducted. DLC1.1 was calculated for extrapolation of 50 years-extreme events using several probability distribution functions and fitting methods. And DLC1.3 was calculated for up to seven different values of scale factor (c) with 2≤c≤5 in steps of 0.5. Finally, in this study, scale factor (c) that was the value of 4.51was determined.