Principles of constructing a measuring current transformer based on photon echo

1997 
For a construction of the opto-electronic current transformer the effect of rotating of the photon echo (PE) polarization vector is offered. As an active ambience allowing get the photon echo the vapors of molecular iodine are used. The theoretical model of the opto-electronic current transformer (OECT) is discussed. The explanatory graphs of the n echo polarization vector rotating effect, as well as the principle scheme of the current measurement, are shown in the paper.© (1997) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.