Summary Purpose To compare the anterior segment optical coherence tomography (AS-OCT) measurements of eyes with pigment dispersion syndrome (PDS) and ocular hypertension (OHT) before and after neodymium:yttrium-aluminum-garnet (Nd:YAG) laser peripheral iridotomy (LPI). Methods A total of 23 eyes of 23 patients with PDS and OHT with features of PDS were included in this retrospective study. All of the eyes with PDS and OHT were examined by AS-OCT before and after Nd:YAG LPI. Anterior chamber depth, angle opening distance 500, angle opening distance 750, trabecular iris space 500, trabecular iris space 750 and scleral spur angle, iris bowing and iris shape were measured with AS-OCT by the same examiner. Results The differences in all parameters before and after Nd:YAG LPI were statistically significant. Iris configuration was concave in all eyes prior to iridotomy. After Nd:YAG laser iridotomy, the iris configuration became convex in 7 eyes, flat in 9 eyes and remained concave in 7 eyes. Conclusion Nd:YAG laser peripheral iridotomy is an effective method for reversing the iris concavity and iris bowing in pigment dispersion syndrome.