Antidigoxin-Fab-Fragmente bei suizidaler Digoxin-Intoxikation: Erfolgreiche Behandlung von rezidivierendem Kammerflimmern
2008
: A 49-year-old woman took about 12.5 mg digoxin with suicidal intent. Severe arrhythmias, including recurrent ventricular fibrillation, occurred. Sheep Fab fragments of digoxin-specific antibodies were administered i. v. at a dose of 480 mg. Serum free-digoxin concentration fell within half an hour to 0, with simultaneous rise of total digoxin from 13 micrograms/l to a maximum of 176 micrograms/l after 2 hours. At the same time there was marked improvement in the clinical condition with restoration of a stable sinus rhythm. There were no side effects to the Fab fragment administration.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
0
References
8
Citations
NaN
KQI