Automated Structured Reporting for Thyroid Ultrasound: Effect on Reporting Errors and Efficiency

2020 
Abstract Purpose To compare the effectiveness of different reporting templates using the ACR Thyroid Imaging Reporting and Data System (TI-RADS) for thyroid ultrasound. Methods In this retrospective study, four radiologists implemented ACR TI-RADS while dictating 20 thyroid ultrasounds for each of four different templates: free text, minimally structured, fully structured, fully structured and automated (embedded software automatically sums TI-RADS points, correlates with nodule size, and inserts appropriate recommendation into report impression). In total, 80 reports were constructed per template type. Frequencies of different errors related to ACR TI-RADS were recorded: errors in point assignment, point addition, risk-level assignment, and recommendation. Reporting times were recorded, and a survey about using the template was administered. Differences in error rates were compared using χ2 and Fisher’s exact tests, and differences in reporting times were compared using Kruskal-Wallis tests. Results Across all readers, errors were identified in 27.5% of reports (22 of 80) for the free text template, 28.8% (23 of 80) for the minimally structured template, 18.8% (15 of 80) for the fully structured template, and 0% (0 of 80) for the fully structured and automated template (P Conclusion A structured reporting template for thyroid ultrasound that automatically executed steps of ACR TI-RADS resulted in fewer reporting errors for radiologists.