Successful surgical repair of acute type A aortic dissection without the use of blood products.

2013 
We report successful surgical treatment of type A aortic dissection in a Jehovah’s Witness without the use of any blood products. An interposition graft replacement of the ascending aorta was carried out. This was under right axillo-atrial cardiopulmonary bypass with antegrade cerebral perfusion via right a subclavian and left carotid cannula for 24 minutes at 28oC. Body temperature was kept at 32oC throughout. Autologous transfusion was deployed using cell salvage and a preoperative haemodilution technique. The patient was given tranexamic acid, desmopressin, recombinant factor VIIa, folic acid and epoetin alfa. Patients who object to transfusion represent a significant challenge, especially those who are at a high risk of coagulopathy associated with inherent aortic dissection leading to perturbed haemodynamics, cardiopulmonary bypass and hypothermic circulatory arrest. Type A aortic dissection repair is possible in patients refusing the use of blood products with blood salvage techniques and synthetic ...