INTER-OBSERVER REPRODUCIBILITY OF 15 TESTS USED FOR PREDICTING DIFFICULT INTUBATION
2011
(0.41–0.60), good (0.61–0.80), and excellent (0.81–1.00). Results. Respective coefficients of inter-rater agreement and correlation coefficients were determined for the following parameters: pathologies associated with DI (κ=0.662, AC1=0.990), clinical impression (κ=-0.013, AC1=0.969), modified Mallampati test (κ=0.503, AC1=0.861), upper lip bite test (κ=0.370, AC1=0.897), temporo-mandibular joint movement (κ=0.088, AC1=0.797), max. anteroflexion of C-spine (ICC=0.136, SCC=0.391), max. retroflexion of C-spine (ICC=0.020, SCC=0.284), mandibular length (ICC=0.301, SCC=0.553), neck circumference (ICC=0.832, SCC=0.928), hyo-mental distance (ICC=0.378, SCC=0.472), thyro-mental distance (ICC=–0.002, PCC=0.265), sternomental distance (ICC=0.674, PCC=0.815), and finally, inter-incisor gap (ICC=0.695, PCC=0.785). Two tests (positive history of DI and retrogenia), were excluded from calculation because no positive cases were found. Conclusion. Best inter-rater agreement was found for the assessment of neck circumference while the highest discrepancies between raters were in goniometrically-measured mobility of the C-spine. Many of the pre-operative airway tests had only fair inter-observer reproducibility. This may be one reason why models for predicting difficult intubation are not universally reliable.