Measured energy expenditure in critically III infants and young children

1988 
Abstract Technological limitations have impeded accurate energy expenditure assessment in critically ill infants and young children. Instead, a predicted energy expenditure (PEE) is derived based on weight, heat loss, activity, growth requirements, and degree of stress. This study compared actual measured energy expenditure (MEE) with conventional predicted values in 20 critically ill infants and children using a validated metabolic cart designed for use in this age group. All patients were studied either within 4 days of major surgery or during an acute disease process necessitating intensive care. All were severely stressed clinically and were studied while mechanically ventilated in a temperature-controlled environment. The study interval ranged from 1 to 12 hr and averaged 4 hr after a stabilization period of 30 min. The mean MEE was significantly lower than the mean PEE (52.2 ± 16 kcal/kg/day vs 101.8 ± 17 kcal/kg/day, P