Mid- to long-term aortic valve-related outcomes after conventional repair for patients with interrupted aortic arch or coarctation of the aorta, combined with ventricular septal defect: the impact of bicuspid aortic valve

2014 
OBJECTIVES: Bicuspid aortic valve (BAV) is a common risk factor for valve-related problems and occurs more frequently in patients with an interrupted aortic arch (IAA) or coarctation of the aorta (CoA), combined with a ventricular septal defect (VSD), than in the general population. We have been using conventional repair for patients with IAA/CoA+VSD, including those with a very small aortic valve (AV). We retrospectively investigated the outcomes of these patients from the perspective of valve morphology. METHODS: Between 2000 and 2012, 50 consecutive patients underwent conventional repair for CoA/IAA with VSD [one-stage repair, 44 (88%); staged repair, 6 (12%)]. The criteria for conventional repair were as follows: an AV annulus diameter (AVD) z-score of >�6.0; mitral valve annulus diameter z-score of >�3.0; without retrograde flow in the proximal arch. Sixteen (32%) patients had BAV (Group B); the remaining 34 (68%) patients had a tricuspid AV (Group T). The surgical outcomes in both groups were investigated. RESULTS: No mortality occurred in the cohort. The median follow-up times were 6 years and 3 months (6 months to 11 years and 8 months) and 6 years and 2 months (4 months to 11 years and 4 months) in Groups B and T, respectively (P> 0.05). The preoperative data (median age at repair, median body weight and median AVD) were comparable in the two groups (P> 0.05). Two patients (4%) underwent reintervention in the aortic arch: 1 patient underwent balloon angioplasty for re-coarctation; the other removal of the interposed graft because of somatic growth. In both groups, the AVD became significantly larger at the 1-year follow-up, approximating the normal value. Three (6%) patients underwent a total of eight valve-related reinterventions (balloon angioplasty, 6; Ross operation, 1; valve replacement, 1). All three had BAV, and the AVD was 3.8–5.6 mm (z-score, �3.4 to �1.6). The 5-year valve-related reintervention-free survival rate was 76% and 100% in Groups B and T, respectively (P< 0.01). CONCLUSIONS: The long-term outcomes after conventional repair under our criteria were acceptable. BAV was a significant risk factor for valve-related reinterventions after conventional repair for IAA/CoAwith VSD.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    24
    References
    16
    Citations
    NaN
    KQI
    []