Navigation of a 6-French guiding sheath into the common carotid artery using a tri-axial catheter system in transbrachial carotid artery stenting:
2019
Background and purposePlacement of a large-bore guiding sheath or catheter into the common carotid artery (CCA) is crucial in transbrachial carotid artery stenting (CAS). Herein, we describe technical tips for the navigation of a 6-French guiding sheath into the CCA using a tri-axial catheter system in transbrachial CAS.Materials and methodsA total of 27 patients underwent transbrachial CAS. For the right side, a 6-French straight guiding sheath was navigated directly into the CCA using a tri-axial catheter system, with a 4-French Simmons catheter placed through a 6-French straight guiding catheter. For the left side, a 6-French Simmons guiding sheath was navigated into the CCA using a tri-axial catheter system, with a 4-French Simmons catheter placed through a 6-French Simmons guiding catheter. After the placement of a 6-French guiding sheath into the CCA, CAS was performed under distal filter or balloon protection.ResultsFifteen patients had a right carotid stenosis and 12 patients had a left carotid st...
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
15
References
1
Citations
NaN
KQI