We report a measurement of the total photoelectron yield of gold as a function of the incident x‐ray polarization. Polarized x rays with energies of 2.5, 2.7, and 4.0 keV were used to excite a gold photocathode at a glancing incidence angle between 5° and 50°. Contrary to a previous report, we found no measurable polarization dependence for all three x‐ray energies. We conclude that the modulation factor, i.e., the fractional change of the total yield when the polarization state is varied, is less than 4%.