Evaluation of an heterogeneous group of patients with von Willebrand disease using an assay alternative to ristocetin induced platelet agglutination
2015
Summary
Background
Diagnosis of von Willebrand disease (VWD) type 2 usually relies on the discrepancy between the von Willebrand factor (VWF) ristocetin cofactor activity (VWF:RCo) and VWF antigen (VWF:Ag). Type 2B patients can be discriminated from other qualitative VWD variants by using ristocetin-induced platelet agglutination (RIPA) test. The major limitation of RIPA is the requirement of fresh blood sample.
Objectives
In this study, we evaluated the VWF gain-of-function mutant GPIb binding (VWF:GPIbM) and VWF:RCo assays to investigate whether the VWF:GPIbM/VWF:RCo ratio was able to identify the type 2B variant among an heterogeneous VWD population, previously characterized following the ISTH-SSC guidelines.
Patients/methods
Seventy-six VWD patients and 31 healthy subjects were evaluated by using VWF:Ag, VWF:RCo, and VWF:GPIbM assays.
Results
The mean (minimum–maximum values) VWF:GPIbM/VWF:RCo ratio was higher in type 2B patients (2.53, 0.84–6.11) than in healthy controls (1.05, 0.87–1.34), type 1 (0.85, 0.51–1.15), 2A (1.20, 0.36–2.82), and 2M (1.07, 0.91–1.38) (P < 0.0001). Type 2B variants were divided into four groups (A, B, C, and D) according to their different multimeric patterns. The mean value of the VWF:GPIbM/VWF:RCo ratio in the four groups showed an increasing trend from group A (1.08) to D (3.69), proportional to the loss of high molecular weight multimers. Among 32 type 2B patients, previously diagnosed with RIPA, 8 (mainly with a type I New York/Malmo phenotype) were not confirmed using the VWF:GPIbM/VWF:RCo ratio.
Conclusions
Whenever the RIPA test is not feasible, the VWF:GPIbM/VWF:RCo ratio might help to identify severe type 2B VWD patients.