Hydrolaparoscopy in the rabbit: A fine model for the development of operative fetoscopy

1994 
Objective: Our goal was to become adept at performing laparoscopic procedures within a fluid medium and at using miniature instruments in a small animal model. Study Design: Adult female New Zealand rabbits underwent carbon dioxide laparoscopy while they were under general anesthesia with the use of 2 mm instruments. The abdominal cavity was filled with lactated Ringer's solution. Visualization of the intraabdominal organs and surgical procedures were performed below the fluid level. Results: Excellent visualization of the abdominal organs below the fluid level was obtained. Several surgical tasks were accomplished, including cutting and coagulation of the uterine horns with monopolar electrocautery, creation of a defect in the mesovarium and mesometrium, extracorporeal knot tying, and intraabdominai cutting of suture material. Relatively high amounts of energy were needed during electrocautery within the liquid medium (> 25 W). Occasional fluid and gas leakage through the skin punctures was prevented with accessory clamps. Conclusion: Hydrolaparoscopy can be performed in the rabbit with miniature instruments. As it simulates the human intraamniotic environment, it is a useful model for the development of operative fetoscopy.