Retrograde Type A Aortic Dissection After Endovascular Stent Graft Placement for Treatment of Type B Dissection

2009 
Background— Retrograde type A aortic dissection has been deemed a rare complication after endovascular stent graft placement for type B dissection. However, this life-threatening event appears to be underrecognized and is worth being investigated further. Methods and Results— Eleven of 443 patients developed retrograde type A aortic dissection during or after stent grafting for type B dissection from August 2000 to June 2007. Of these 11 patients, 3 had Marfan syndrome. The Kaplan–Meier estimate of the rate of freedom from this event at 36 months is 97.4% (95% confidence interval, 0.95 to 0.99). The new entry was located at the tip of the proximal bare spring of the stent graft in 9 patients, was within the anchoring area of the proximal bare spring in 1, and remained unknown in 1 patient. Eight patients were converted to open surgery, and 2 received medical treatment. One patient suddenly died 2 hours after the primary stent grafting, and 2 died within 1 week after the surgical conversion, so mortality r...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    43
    References
    207
    Citations
    NaN
    KQI
    []