Decontamination and Reuse of N95 Respirators with Hydrogen Peroxide Vapor to Address Worldwide Personal Protective Equipment Shortages During the SARS-CoV-2 (COVID-19) Pandemic

2020 
The SARS-CoV-2 (COVID-19) pandemic has placed a tremendous amount of strain on resources in the health care setting. One of the most pressing issues is the rapid depletion of personal protective equipment (PPE) used in the care of patients. This is a significant concern for health care workers’ health and safety. Many entities have depleted or soon will exhaust their stockpile of PPE despite adopting PPE-sparing practices as the number of COVID-19 cases in the United States increases at an almost exponential rate and manufacturers struggle to keep up with the worldwide demand. This potential shortage is particularly concerning for commonly used N95 respirators and powered-air purifying respirators (PAPRs). Recently, the US Occupational Safety and Health Administration (OSHA)1 even temporarily suspended the requirement to perform annual fit testing of respirators to allow entities to conserve respirators and preserve them for patient care. These measures are unprecedented and highlight the urgent need for entities to develop solutions to proactively address what could be potentially a grave occupational health issue. At Duke University and Health System, we have evaluated and will begin using hydrogen peroxide vapor to decontaminate and reuse N95 respirators. In this communication, we briefly discuss the decontamination validation process and post-decontamination performance validation conducted at Duke. This validation, which is supported by previous laboratory testing, funded by the US Food and Drug Administration (FDA), demonstrated that N95 respirators still met performance requirements even after decontamination with hydrogen peroxide vapor in the laboratory setting for over 50 times.2 While previous studies have shown the applicability of the hydrogen peroxide vapor process, we have also confirmed that the respirator still functions as designed, using our standardized human N95 fit testing methodology. We will now use this internally validated and Duke Institutional Biosafety Review Committee (IBRC)–approved laboratory decontamination process in the clinical setting to dramatically extend the life of our N95 respirators. We hope that sharing our processes through this brief communication can help other entities with access to hydrogen peroxide vapor to evaluate the potential applicability of this technology at their facility or partner with those who may already have this capability, including other private-sector life science organizations. Process/Method We, like others, have implemented many Centers for Disease Control and Prevention (CDC)–approved N95 reuse practices, including employees reusing their own N95s for the duration of their shifts. However, this alone may not be adequate to meet our anticipated need with various centers reporting multiple-fold higher use of PPE as their caseload increases. In the interest of our workforce safety, the goal was thus to extend the life of our existing supply. Duke University houses one of the National Institute of Allergy and Infectious Diseases (NIAID) Regional Biocontainment Laboratories (RBLs) as part of a nationwide network of high-containment laboratories and has extensive experience with the use of hydrogen peroxide vapor decontamination. In addition, Duke University Health System had past experience with hydrogen peroxide vapor in the clinical setting as part of previous high-consequence pathogen preparedness exercises. The Duke RBL, a biosafety level 3 (BSL-3) facility, contains a room specifically designed to use hydrogen peroxide vapor to decontaminate laboratory equipment and has been operational for over a decade. This room currently uses a Bioquell (Horsham, PA, USA) ClarusTM C system with a 35% hydrogen peroxide solution and distribution system to disperse hydrogen peroxide vapor into the room in a uniform fashion. In addition, we are evaluating the new Bioquell Z-2 and Bioquell ProteQ systems that will provide increased capacity and flexibility to our reprocessing needs. The FDA-funded project, referenced previously, validated the decontaminat on of N95 respirators with hydrogen peroxide vapor for over 50 cycles with the reuse limiting factor being the elastic straps that started to show degradation.2 To address this, we plan to decontaminate and reuse N95s up to 30 cycles with a quality assurance (QA) step to ensure both qualitative and quantitative degradation has not occurred. A cohort of respirators will be decontaminated with every cycle and will be used in standardized quantitative fit testing to ensure the integrity of the respirators is maintained over many decontamination cycles. Procedures Approximately 100 3M (St. Paul, MN, USA) 1860 N95s, previously used in quantitative employee fit testing, were collected and laid out on stainless steel wire racks in our hydrogen peroxide vapor processing room in the RBL. The hydrogen peroxide vapor run consisted of the following 5 stages: conditioning, pregassing, gassing, gassing dwell, and aeration. The existing RBL hydrogen peroxide vapor standard operating procedure (SOP) was employed and requires that the processing room attain a 480+-ppm level of hydrogen peroxide vapor with a “gassing” time of 25 minutes and a “gassing dwell” time of 20 minutes. At the end of a cycle, during the aeration stage, fresh air was introduced into the room to increase the rate of catalytic conversion of hydrogen peroxide vapor into oxygen and water. This procedure leaves no residue other than water. When sufficient time had passed, we used a PortaSens II sensor (Analytical Technology, Inc., Collegeville, PA, USA) to ensure hydrogen peroxide levels were below the OSHA permissible exposure limit3 (PEL) of 1.0 ppm prior to entering the room. In addition, we validated the efficacy of the decontamination process by using 9 individual 6-log biological indicators (Geobacillus stearothermophilus spores). See Figure 1 for representation of the decontamination setup and placement of biological indicators. [truncated]
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    102
    Citations
    NaN
    KQI
    []