Tritium decontamination on the surface of Tokamak Fusion Test Reactor (TFTR) bumper limiter tiles used during the Deuterium-Deuterium (D-D) phase of TFTR operations was investigated employing an ultra violet light source with a mean wavelength of 172 nm and a maximum radiant intensity of 50 mW/cm 2 . The partial pressures of H 2 , HD, C and CO 2 during the UV exposure were enhanced more than twice, compared to the partial pressures before UV exposure. In comparison, the amount of O 2 decreased during the UV exposure and the production of a small amount of O 3 was observed when the UV light was turned on. Unlike the decontamination method of baking in air or oxygen, the UV exposure removed hydrogen isotopes from the tile to vacuum predominantly in forms of gases of hydrogen isotopes. The tritium surface contamination on the tile in the area exposed to the UV light was reduced after the UV exposure. The results show that the UV light with a wavelength of 172 nm can remove hydrogen isotopes from carbon-based tiles at the very surface.