Evaluation of the physical and biological dosimetry methods in iodine-131-treated patients

2018 
The aim of the study was to compare physical and biological dosimetry methods in iodine-131 (I-131)-receiving patients. The present study comprised of 47 patients (mean age: 47.9 ± 15.8 years), treated with I-131. Group I consisted of 17 patients with hyperthyroidism and mean administered activity of this group was 432.9 ± 111 MBq. There were 15 follow-up patients of differentiated thyroid cancer (DTC) in Group II with mean administered activity of 185 ± 22.2 MBq, who were administered scanning dose of I-131. Group III comprised of 15 patients with DTC, ablated with high-dose of I-131, and this group's mean administered activity was 4347.5 ± 695.6 MBq. The whole-body absorbed doses were calculated in all patients both with the Medical Internal Radiation Dosimetry (MIRD) method using MIRDOSE3 software and cytokinesis-block micronucleus (MN) assay-based MN analysis and were compared. The whole-body absorbed dose, calculated by MIRD method, showed very good correlation with the administered I-131 activity (r = 0.89, P r = 0.52, P P P P P = 0.087) in the entire study population and the correlation was moderate ( r = 0.73, P
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    31
    References
    1
    Citations
    NaN
    KQI
    []