An ultraviolet Thomson-scattering system has been designed and implemented on the Shenguang-III laser facility, a 48-beam, 3ω (351 nm), 180 kJ-level laser driver for high energy density physics and inertial confinement fusion researches. The 4ω (263.3 nm) probe beam of the Thomson-scattering system is injected from the north pole (top) of the target chamber, with an assistant beam-pointing monitor to achieve high pointing accuracy. The Thomson-scattered light is collected by a double-Cassegrain optical transmission system, which provides an achromatic image over a wide wavelength range of 200–800 nm. A novel on-line alignment method is developed and applied to the diagnostic system, ensuring a volumetric positioning accuracy of ∼30 μm for the scattering volume. An online calibration is also conducted to provide the wavelength benchmark and the spectral resolution of the system. This Thomson-scattering system has been tested in a complicated experimental environment with gas-filled hohlraums, and a high-qu...