Role of diffusion weighted magnetic resonance imaging in a rat model of testicular torsion

2016 
Objective:The purpose of this study was to investigate the usefulness of diffusion-weighted imaging (DWI) in the detection of different degrees of testicular torsion (TT) at the 8th hour and testicular salvageability at the 24th hour of torsion.Methods:31 rats were randomly classified into 4 groups. In Group 1 (sham-control group), the left testicle was kept outside and replaced. Left testicles were kept outside and twisted 360° in Group 2, 720° in Group 3 and 1080° in Group 4. Later, DWI was performed at 8th and 24th hours. After DWI, bilateral radical orchiectomy and histopathological examination were performed. Apparent diffusion coefficient (ADC) maps were obtained with b-factors of 0 and 800 s mm−2. Comparisons of ADC values and damage in testicles were performed with Kruskal–Wallis test.Results:Sensitivity of DWI in the diagnosis of TT was 12.5% for 360° torsion, 100% for 720° torsion and 1080° torsion at the 8th hour of torsion. Mean ADC values of the left testicles increased significantly at the 2...