J series thruster thermal test results
1982
Test experience with J series ion thrusters have indicated that the present thruster design may result in excessive temperatures in areas which utilize organic materials such as wire insulation, with the resultant outgassing and potential contamination of insulating materials. Further, it appears that thermal data obtained with earlier thruster designs, such as the 700 series thruster, may not be directly applicable to the J series design. Two J series thrusters were fitted with thermocouples and critical temperatures measured for a variety of configurations and operating parameters. Completely enclosing the thruster to reduce facility contamination significantly increased temperatures prompting the selection of a compromise geometry for life testing. The operating parameter having the largest effect on temperatures was discharge power, while beam power affected little else than extraction system temperatures. Several off-normal operating modes were also investigated. Data believed to be sufficient to effectively modify existing thermal models were obtained from the tests.
Keywords: