Circadian variations in coagulation and fibrinolytic factors among four different strains of mice.

2007 
This study examined circadian variation in coagulation and fibrinolytic parameters among Jcl:ICR, C3H/HeN, BALB/cA, and C57BL/6J strains of mice. Plasma plasminogen activator inhibitor 1 (PAI‐1) levels fluctuated in a circadian manner and peaked in accordance with the mRNA levels at the start of the active phase in all strains. Fibrinogen mRNA levels peaked at the start of rest periods in all strains, although plasma fibrinogen levels remained constant. Strain differences in plasma antithrombin (AT) activity and protein C (PC) levels were then identified. Plasma AT activity was circadian rhythmic only in Jcl:ICR, but not in other strains, although the mRNA levels remained constant in all strains. Levels of plasma PC and its mRNA fluctuated in a circadian manner only in Jcl:ICR mice, whereas those of plasma prothrombin, factor X, factor VII, prothrombin time (PT), and activated partial thrombin time (APTT) remained constant in all strains. These results suggest that genetic heterogeneity underlies phenotyp...