One size does not fit all: Factors associated with increased frequency of radiation overexposure alerts based on fixed-alert thresholds.

2021 
Abstract Objectives Quantify the expected rate of CT radiation dose alerts for three body regions using accepted radiation dose benchmarks and assess key determinants of alert frequency. Methods This IRB-approved retrospective cohort study evaluated consecutive CT examinations performed between July and December 2013 within an academic medical system. CTDIvol x-ray tube output metrics were compared to the body-region-specific benchmark levels, Achievable Doses (AD), Diagnostic Reference Levels (DRL), and Dose Notification Values (DNV). A logistic regression model for the simulated alerts was fit as a function of the independent predictors: scanner, body region, gender, weight, and age. Results For 17,000 exams, the proportion of events triggering alerts increased with patient weight. Significant covariates were scanner, body region, patient weight and patient age (all p  Conclusion Alert frequency was significantly correlated with weight, age, body region and scanner. Controllable factors include scanner functionality and associated protocol optimization. Patient factors driving alert frequency are predominantly weight, and to a lesser degree, age. Size-agnostic fixed dose thresholds can frequently produce false positive alerts in appropriately performed exams of large patients, while missing opportunities to identify outlier scans of higher-than-expected dose in small patients.
    • Correction
    • Source
    • Cite