We demonstrate the potential of a hydrothermal method-grown ZnO as a high-spatial resolution imaging device for in-situ soft X-ray laser diagnostics by characterizing the exciton emission patterns. By plotting the emission pattern radii at each position, we estimated the evolution of the beam radius around the focal point. The beam profile of the Ni-like Ag ion plasma laser was estimated from the waist radii as 29 and 21 ?m, the divergence angle as 7.2 and 11 mrad and the M2 factor as 47 and 50 in the horizontal- and vertical-axis, respectively. Spatial resolution of the magnifier was estimated to be 6 ?m and is expected to improve by optimizing the optics of the magnifier and using a telescope. Our results would enhance the use of ZnO as an imaging device that would play a crucial role in the development and application of soft X-ray light sources.