Aim: To improve the diagnostic accuracy of immuno-PCR (I-PCR) in tuberculosis (TB) patients by using functionalized gold nanoparticles (AuNPs) coupled with detection antibodies and oligonucleotides, and magnetic beads (MBs) conjugated with capture antibodies in the liquid phase. Materials & methods: MB-coupled AuNP-based I-PCR (MB-AuNP-I-PCR) assay was designed to detect a cocktail of Mycobacterium tuberculosis MPT64 and CFP-10 proteins in bodily fluids of TB patients. Results: The sensitivities of 89.3 (n = 94) and 78.1% (n = 73) were observed in pulmonary TB and extrapulmonary TB patients, respectively, with specificities of 97.9-98.3%. Notably, the sensitivities attained by MB-AuNP-I-PCR in smear-negative pulmonary TB and extrapulmonary TB patients were significantly higher (p < 0.05-0.001) than Magneto-ELISA and GeneXpert assay. Conclusion: The improved technology, as well as enhanced diagnostic accuracy of MB-AuNP-I-PCR, may lead to development of an attractive diagnostic kit.