Design of Langmuir probe diagnostic system for the upgraded lower tungsten divertor in EAST tokamak

2018 
In order to achieve long-pulse H-mode plasma scenario over 400 s with high heating power in the Experimental Advanced Superconducting Tokamak (EAST) device, the lower graphite divertor will be upgraded into a tungsten (W) divertor with active water cooling, which consists of the W/Cu monoblock units and the W flat-tile units as the divertor plasma facing components. As a fundamental diagnostic tool, the divertor Langmuir probe (Div-LP) diagnostic system will be upgraded accordingly. This paper presents the design of two kinds of new Div-LP systems, which are planned to be utilized on the W/Cu monoblock units and the W flat-tile units for the upgraded lower tungsten divertor, respectively, including their structures and preliminary poloidal and toroidal layouts. The Div-LP diagnostic system can measure the plasma parameters with the schemes of triple-probe, double-probe, and single-probe, to obtain the spatial and temporal distribution of plasma behavior on the divertor targets, which is useful for the dis...