Thermal Limits for Passive Safety of Fusion Reactors

1989 
The thermal response of the first wall and blanket due to power/cooling mismatch in the absence of operation action is examined. The analyses of coolant and power transients are carried out on six reference blanket designs representing a broad range of fusion first wall and blanket technology. It is concluded that the requirement of plant protection will impose sufficiently stringent peak neutron wall loading limits to avoid a serious threat to the public. It is found that for the D-T design,s the operating wall loading may have to be limited to 3 - 8 MW/m/sup 2/ for passive plant protection, depending on the plant design.