[Establishment of an isolated porcine liver machine perfusion model for high-intensity focused ultrasound studies].

2012 
Objective To explore the feasibility of establishing an isolated porcine liver machine perfusion model and assess its value in high-intensity focused ultrasound studies.Methods Twenty-one isolated porcine livers were perfused with autologous blood for 4 h through dual vessels(portal vein and hepatic artery) cannulation using an extracorporeal circulation machine under a subnormothermic perfusion condition.The perfusion model was assessed by monitoring the liver color, texture,liver weight gain,hemodynamic parameters,color Doppler flow imaging,bile output and histopathology.Results Nineteen isolated porcine livers were successfully cannulated with dual vessels,and failure of hepatic artery intubation occurred in two porcine livers.After machine perfusion for 4 h,the isolated livers maintained a soft texture with stable hemodynamic levels within relative normal physiological ranges.The bile output was more than 3 ml/h within the initial 3 h of perfusion.Histopathological examination demonstrated no morphological or structural changes of the liver tissues. Conclusion The isolated porcine liver perfusion model is stable and feasible,and can be used for high-intensity focused ultrasound studies.