Determinación de Parámetros de Diseño Y Desinfección con Ozono de un Efluente Municipal

2005 
2UFC/mL of Pseudomonas aeruginosa, to simulate a potential contamination. This pathogen microorganism is frequent in this wastewater and it is resistant to the chloration. The results indicated that a dose of 7 mg/L during 5 minutes is enough. The ozone reduces the environmental impact as disinfection stage, since the high chlorine doses generate residual concentrations higher than 3 mg/L. Which is not desirable and it constitutes an ecological risk for the population health, that is supplied of the water receiver body. A design of the contact system was proposed. The chlorination tank can be used as ozonization reactor with a minimum of modifications. The investment costs can be reduced. This diminishes the investment cost for construction cost reduction. A bubble reactor with double baffles is proposed. It is composed by two mixing chambers. The countercurrent contact among the phases is guaranteed. In the third chamber ozone is not injected. The double baffles are recommended to avoid the short circuit effect.