Review of 31 cases of anterior thoracolumbar fixation with the anterior thoracolumbar locking plate system

1999 
Anterior fixation devices for the thoracolumbar spine have gained wide acceptance as viable alternatives to long-segment posterior fixation in cases of thoracolumbar spine trauma. This review was undertaken to evaluate the safety and efficacy of the Synthes anterior thoracolumbar locking plate (ATLP) system. Over a 3-year period, 31 patients with unstable traumatic fractures of the thoracolumbar spine underwent corpectomy, placement of a structural bone graft, and anterior fixation in which the Synthes ATLP system was used. Long-term follow-up data were obtained in 29 patients. Two patients were lost to follow up, one at 4 months and the other at 1 year. In the remaining patients, the average length of follow up was 20 months. In all patients radiographic evidence of solid bone fusion was demonstrated on follow-up plain x-ray films, and there were no signs or symptoms of pseudarthrosis. No patient suffered neurological deterioration as a result of surgery, and there was relatively little morbidity associa...