Do vitreous fibers break in the lung

2007 
In order to determine whether breakage of long vitreous fibers in the lung could be responsible for removing significant numbers of these fibers, an intratracheal instillation study was done with a preparation consisting of mostly long fibers of two different types. Following instillation of both fibers, laboratory rats were sacrificed at 6 times up to 14 days. The NK (conventional borosilicate glass) fiber preparation had about 20% short fibers (length ≤ 15 μm) initially, and fibers recovered from the lungs remained at that proportion for the entire 14 days. But the HT (a new rock or stone wool) fiber preparation, which had about 5% short fibers initially, jumped to about 50% short fibers at 2 days and remained at that proportion for the rest of the study. The appearance of many short HT fibers where there were few initially is conclusive evidence that these long fibers break, and it explains their rapid removal from the lung. Since the HT fibers dissolve rapidly at acid pH, but slowly at the near neutra...