Investigation of the lateral spread of Er ions implanted in 6H-SiC

2010 
It is very important to consider the distribution of range, range straggling and lateral spread of ions implanted into semiconductor materials in design and fabrication of semiconductor integration devices by ion implantation. Er ions with energy of 400 keV were implanted in 6H-SiC crystal samples under the angles of 0°, 45° and 60°, respectively. The lateral spread of Er ions with dose of 5×10 15 cm -2 at energy of 400 keV implanted in 6H-SiC crystal were measured by Rutherford backscattering technique. The measured lateral spread is compared with TRIM98 and SRIM2006 codes prediction. It is seen that the experimental lateral spread well justifies the theoretical values. The value from TRIM98 agrees somewhat better to the experimental data than the value obtained based on SRIM2006.