Occupational HIV infection in a research laboratory with unknown mode of transmission: A case report
2016
A lab-worker was infected with HIV-1 in a biosafety level-2 of containment, without any apparent breach. Through full-genome sequencing and phylogenetic analyses, we could identify the source of infection in a replication-competent clone, unknowingly contaminating a safe experiment. Mode of transmission remains unclear. Caution is warranted when handling HIV-derived constructs.