Contaminação do ambiente odontológico por aerossóis durante atendimento clínico com uso de ultrassom

2011 
Durante um atendimento odontologico ha dispersao de respingos e aerossois contendo microorganismos patogenicos, que podem ser transmitidos atraves da saliva, sangue e secrecoes bucais. O objetivo deste trabalho foi verificar o grau e a extensao da contaminacao por aerossois no ambiente odontologico em uma clinica de atendimento coletivo na ausencia do fluxo normal de pessoas. Foram realizados procedimentos de raspagem supragengival com ultrassom em dez pacientes por cinco minutos, com intervalo de vinte minutos entre eles. Durante cada atendimento, placas de Petri contendo meio de cultura Agar BHI (Brain Heart Infusion) suplementado com sangue de carneiro (5%) foram dispostas em cinco areas do consultorio odontologico. Um total de quarenta e cinco placas foi coletado e posteriormente incubado por 24 horas a 36oC. Constatou-se crescimento bacteriano semelhante em todas as areas, inclusive no encosto da cabeca da cadeira vizinha (p>0,05). Houve um predominio de estafilococos (55,84%), seguidos de bacilos gram-positivos e gram-negativos (20,77%). Concluiu-se que mesmo em uma area restrita de atendimento e com a presenca de barreiras fisicas, ocorre contaminacao via aerossois alem dos limites da area do consultorio. Cuidados relacionados a biosseguranca pelos operadores e circulantes e restricao de materiais nas bancadas proximas as areas de atendimento sao medidas importantes para evitar contaminacao cruzada During dental procedures, aerosols and droplets contaminated with pathogenic microorganisms may be transmitted through saliva, blood and oral fluids. Theaim of this study was investigate the degree and limits of contamination produced by aerosols in a multichair school clinic during a non attendance day. Supragingival scaling using ultrasonic device was done in ten patients at their anterior mandibular teeth during five minutes with twenty minutes interval between them. During each procedure blood agar plates were placed around the operatory area in five different positions and changed after each patient. A total of forty-five plates were collected and incubated for 24 h at 36oC. There was similar bacterial growth in all areas, including neighborchair (p>0.05). Bacterial growth was present at all plates, and Stafilococus sp. were predominant (55.84%) followed by gram-positive and gram-negative rods (20.77%). Inspite of the limited amount of people at the clinic and the presence of barriers present between areas, a great amountof contaminated aerosols were detected beyond the limits of the chair. Safety measures should be taken for all personnel, even those positioned distant from the operative site
    • Correction
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    2
    Citations
    NaN
    KQI
    []