High-efficiency, High-current Optimized Main-linac ERL Cryomodule

2018 
The Main Linac Cryomodule (MLC) prototype is a key component of the Cornell-BNL ERL Test Accelerator (CBETA) project, which is a 4-turn FFAG ERL currently under construction at Cornell University. This novel cryomodule is the first SRF module ever to be fully optimized simultaneously for high efficient SRF cavity operation and for supporting very high CW beam currents. After a successful initial MLC testing, the MLC has now been moved into its final location for the CBETA ring. For a first beam test of the MLC and CBETA, the Cornell ERL high voltage DC gun and SRF injector cryomodule were connected to MLC via an entry beam line; a beam stop assembly was also installed at the exit line. In this paper, we summarize the performance of this novel ERL cryomodule including the results of the first beam test and the additional tests focused on RF field stability and cavity microphonics.