A comparative study between the dynamic method and passive can technique of radon exhalation measurements from samples
2015
Abstract A comparative study has been carried out between the SSNTD based ‘can’ technique and active monitors based dynamic method using nine different samples, eight of granite and one of phosphogypsum. Besides radon ( 222 Rn) exhalation, thoron( 220 Rn) exhalation and 226 Ra and 232 Th content were also measured. The results are: (i) presence of significant thoron exhalation from samples and (ii) observation of thoron interference and leak (~0.05 h −1 ) from the ‘can’ in the SSNTD based ‘can’ technqiue. The study unequivocally demonstrates the presence of intrinsic uncertainty in SSNTD based ‘can’ technique. Instead, dynamic method offers a more reliable and faster method.