Performance of Different Prediction Equations for Estimating Renal Function in Kidney Transplantation

2004 
Numerous formulas have been developed to estimate renal function from biochemical, demographic and anthropometric data. Here we compared renal function derived from 12 published prediction equations with glomerular filtration rate (GFR) measurement by plasma iohexol clearance as reference method in a group of 81 renal transplant recipients enrolled in the Mycophenolate Mofetil Steroid Sparing (MY.S.S.) trial. Iohexol clearances and prediction equations were carried out in all patients at months 6, 9 and 21 after surgery. All equations showed a tendency toward GFR over-estimation: Walser and MDRD equations gave the best performance, however not more than 45% of estimated values were within ±10% error. These formulas showed also the lowest bias and the highest precision: 0.5 and 9.2 mL/min/1.73 m2 (Walser), 2.7 and 10.4 mL/min/1.73 m2 (MDRD) in predicting GFR. A significantly higher rate of GFR decline ranging from −5.0 mL/min/1.73 m2/year (Walser) to −7.4 mL/min/1.73 m2/year (Davis–Chandler) was estimated by all the equations as compared with iohexol clearance (−3.0 mL/min/1.73 m2/year). The 12 prediction equations do not allow a rigorous assessment of renal function in kidney transplant recipients. In clinical trials of kidney transplantation, graft function should be preferably monitored using a reference method of GFR measurement, such as iohexol plasma clearance.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    36
    References
    182
    Citations
    NaN
    KQI
    []