Efficacy of halogen photopolymerization units in private dental offices in Toronto.

2005 
© J Can Dent Assoc 2005; 71(8):587 This article has been peer reviewed. Applied R E S E A R C H The use of resin composites for restoration of Class 1 and 2 preparations has increased significantly in recent years1–3 because of environmental concerns about mercury in amalgam, increasing patient demand for more esthetically pleasing restorations, and the development and marketing of new resin composites.1,2 Although resin composites are available in both auto-polymerized and light-polymerized forms, dentists prefer the light-polymerized composites because of better handling characteristics.4 Most light-polymerized composites contain a light-sensitive absorber such as camphoroquinone, which initiates polymerization by breaking Purpose: Light units used for polymerization of resin composites are subject to deterioration with age, and frequent maintenance is required to maintain optimal efficacy. This study examined the efficacy of quartz–tungsten–halogen light units in private dental offices in Toronto for polymerization of resin composites. Materials and Methods: One hundred dental offices met all selection criteria and agreed to participate in the study. The light intensity was determined for a total of 214 light units. Disk-shaped specimens, 2.5 mm thick, were made from 2 resin composites (Charisma, Heraeus Kulzer; Point 4, Kerr Corp) and were subjected to photopolymerization: Charisma for 20 seconds (99 units) and Point 4 for 20 and 40 seconds (all 214 units). Knoop hardness values for the upper and lower surfaces of each specimen were determined, and relative hardness values (hardness of lower surface/hardness of upper surface × 100) were calculated. Data were analyzed using descriptive statistics, t-tests, 1-way analysis of variance, and simple and multiple linear regression (a = 0.05). Results: The light intensity of the individual units varied widely, from 120 to 1,000 mW/cm 2 . Surface hardness and relative hardness were significantly (p < 0.05) and positively associated with light intensity, and wide ranges in surface hardness and relative hardness values were observed. Mean relative hardness ranged from 34.8% to 57.7%. Conclusions: Light polymerization units in private dental offices displayed a wide range in light intensity, and many had below-recommended levels. Of the resin composite specimens polymerized for 40 seconds with each of the 214 light units, only 10% reached the desired relative hardness of at least 80%. A positive linear relationship was found between light intensity and relative hardness. Increased exposure time resulted in a significant increase in relative hardness. Also, relative hardness was found to be dependent on the brand of composite material used. Dentists should regularly monitor the condition of light units and replace deteriorating parts. MeSH
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    30
    References
    14
    Citations
    NaN
    KQI
    []