Binalarin Ara Kat Döşemelerinin Isil Davranişi Üzerinde Farkli Isi Yalitim Durumlarinin Etkisinin Deneysel Olarak İncelenmesi

2013 
The effect of location of thermal insulation and the type of wall material on the thermal behavior of mezzanine floor beam- slabs' element sections of buildings under temperate climate condition was experimentally investigated. Data obtained from measurements on buildings under service conditions were used. Thermal behaviors of mezzanine floor sections comprising of insulated cavity wall + beam and EPS added wall with exterior insulation + beam were studied in detail in 5 steps. These steps are general behavior of components within the total measurement time of about one month, variation of section temperatures, variation of minimum, maximum and average temperatures measured in the environment and the surfaces, heat flow through the external surface of beam and damping ratios. The results obtained are in line with, the sections of the wall two different insulation types are on thermal behavior of thermal bridges in mezzanine beam slab floors are compared.