MODELS, BIOLOGICAL Hemodynamic, ventilatory and gasometric evaluation of an experimental bronchopleural fistula 1

2015 
ABSTRACTPURPOSE: To investigate the hemodynamic and ventilatory changes associated with the creation of an experimental bronchopleural fistula (BPF) treated by mechanical ventilation and thoracic drainage with or without a water seal. METHODS: Six large white pigs weighing 25 kg each which, after general anesthesia, underwent endotracheal intubation (6mm), and mechanically ventilation. Through a left thoracotomy, a resection of the lingula was performed in order to create a BPF with an output exceeding 50% of the inspired volume. The chest cavity was closed and drained into the water sealed system for initial observation of the high output BPF. RESULTS: Significant reduction in BPF output and PaCO 2 was related after insertion of a water-sealed thoracic drain, p< 0.05. CONCLUSION: Insertion of a water-sealed thoracic drain resulted in reduction in bronchopleural fistula output and better CO 2 clearance without any drop in cardiac output or significant changes in mean arterial pressure.