Influência da espessura de dentina, da constrição apical e do diâmetro do forame apical na precisão de leitura com localizadores foraminais eletrônicos

2010 
Este trabalho teve como objetivo avaliar a influencia da espessura de dentina radicular apical, da constricao apical e do diâmetro do forame apical na precisao de leituras realizadas com os localizadores foraminais eletronicos Mini Apex Locator e Root ZX II®. Foram utilizados 30 incisivos inferiores permanentes unirradiculados de humanos, extraidos, com raizes integras e apices completamente formados e portadores de um unico canal. Por meio de um paquimetro, as espessuras radiculares dos dentes foram medidas, no sentido mesio-distal a 1,0 e a 4,0mm aquem do forame apical. Apos a abertura coronaria, uma lima tipo K no 10, munida de limitador de penetracao, foi introduzida no canal radicular ate que sua extremidade pudesse ser visualizada na altura do forame, com o auxilio de um microscopio optico com aumento de 7,8X. Dessa medida, subtraiu-se 1,0mm, estabelecendo-se o comprimento de trabalho. A dilatacao do canal radicular foi feita, inicialmente, com brocas de Gates Glidden, em ordem numerica decrescente, da numero 5 ate a numero1, ate 4,0mm aquem do forame apical. Os dentes foram fixados em um modelo experimental especialmente desenvolvido para permitir a medicao com os localizadores foraminais eletronicos. Tal modelo era constituido por dois segmentos de PVC: um de menor calibre, com diâmetro correspondente a meia polegada por 2,0cm de comprimento, com as duas extremidades abertas e outro, de maior calibre, com uma das extremidades fechada e com diâmetro interno equivalente ao diâmetro externo do primeiro segmento (3/4 de polegada). No segmento de maior diâmetro, foi feito um orificio lateral que permitiu o posicionamento do eletrodo labial do localizador foraminal eletronico e, para a medicao, no seu interior, foi colocado alginato e, entao, encaixado o componente de menor diâmetro, fazendo com que o apice radicular ficasse imerso no alginato. Foram realizadas as leituras com os localizadores, iniciando-se com a lima tipo K no 10 e seguindo-se... This study evaluated the influence of the apical root dentin thickness, apical constriction and diameter of the apical foramen in the accuracy of readings obtained using the electronic apex locators Mini Apex Locator and Root ZX II ®. The study was conducted on 30 extracted human single-rooted permanent mandibular incisors, with intact and completely formed roots and presenting a single canal. The root thickness of the teeth was measured with a pachymeter in mesiodistal direction, at 1.0 and 4.0mm from the apical foramen. After coronal opening, a 10 K file with a stop was introduced in the root canal until its end could be observed at the level of the apical foramen, with aid of a light microscope with 7.8X magnification. One millimeter was subtracted from this measurement for establishment of the working length. Enlargement of the root canal was initially performed using Gates Glidden burs, in decreasing order, from number 5 to number 1, up to 4.0mm beyond the apical foramen. The teeth were fixated in an experimental model especially designed to allow the measurement with the electronic apex locators. This model was composed of two PVC segments: one smaller, with diameter corresponding to half inch with 2.0cm length, with both ends open; and the other, with larger diameter, with one end closed and internal diameter similar to the external diameter of the first segment (3/4 inch). In the segment with greater diameter, a lateral orifice was made to allow positioning of the lip electrode of the electronic apex locator. For the measurement, alginate was poured and the component with smaller diameter was fitted, so as the root apex was immersed in alginate. Readings were performed using the electronic apex locators, initiating with a 10 K file and following the sequence of instrumentation and measurement up to 130 K file. The 10 K file was used in all diameters. After this stage, the root canals were overinstrumented, i.e. the file tip was introduced until 1.0mm...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    0
    Citations
    NaN
    KQI
    []