51. Comparison of ORL and prostate VMAT treatment plans verifications by ArcCheck® Sun Nuclear™ 3D detector and Varian™ PDIP® module: assessment of the errors detection sensitivity and the capability of each process

2017 
Introduction The complexity of intensity modulation radiation requires a planned dose distribution verification prior treatment. Delivery a patient treatment plan quality assurance can be carried out by EPID, 2D/3D detector or by ionization chamber. In our department, VMAT treatment plans are checked by ArcCheck® Sun Nuclear™ 3D detector and Varian™ PDIP® module. In order to assess the feasibility of reducing the number of verification processes, we studied the detection sensitivity of different errors [1] and the capability of each process. Methods Treatment plans are checked by ArcCheck® Sun Nuclear™ 3D detector + SNC patient™ v6.7.1 software (AC) and Varian™ As 1000 EPID + Varian™ PDIP® v13.0 module (PDIP). For 5 ORL and prostate treatment plans, errors of collimator angulation (1–5°), dose rate (2–3%) and multi-leaf collimator (opening leaves banks from 0.5–1–2 mm) are simulated. Treatment plans are assessed by γ index (3%/3 mm, 2%/2 mm) with a respective passage criteria of 95% and 90% of the total pixels in global and local mode. A database of 80 ORL treatment plans and 30 prostate treatment plans is analyzed in order to check the capability of each process according to the different γ index analysis criterias used. Results As regards the detection sensitivity of errors, according to the analysis criterias of the γ index, the AC and the PDIP respectively make it possible to detect on average: collimator errors from 2° and 3° for the ORL plans and 4° and above 5° for prostate plans; Dose rate errors of 2% for ORL plans and 3% for prostate plans; MLC banks opening errors of 0.5 mm for ORL plans and 0.5 mm and 1 mm for prostate plans. With a fixed analysis criteria, the error detection sensitivity of the AC appears higher than the PDIP. Concerning the database analysis, for the AC, the mean γ indexes with 3%/3 mm global/local mode, and 2%/2 mm global mode are respectively 99,7 [96,3–100]; 95.8 [83.0–100]; 96.8 [81.0–100] for ORL treatment plans and 99.8 [98.8–100]; 98.2 [93.9–100]; 97.6 [90.0–99.8] for prostate treatment plans. The respective CPM capability indices are 5.2; 0.1; 0.9 for ORL treatment plans and 9.2; 1.0; 1.5 for prostate treatment plans. For the PDIP, the mean γ indexes with 3%/3 mm global/local mode and 2%/2 mm global mode are respectively 99.9 [98.8–100]; 97.6 [92.1–100]; 99.0 [93.6–100] for ORL treatment plans and 99.8 [99.0–100]; 99.0 [93.6–99.9]; 98.6 [95.8–100] for prostate treatment plans. The respective CPM capability indices are 17.4; 0.6; 1.5 for ORL treatment plans and 9.8; 1.6; 3.1 for prostate treatment plans. Conclusions The detection sensitivity of the errors appears equivalent between the two processes AC and PDIP by selecting a suited γ index analysis criteria. Analysis with 3%/3 mm local mode appears the most efficient in the detection of error but also leads to a risk of false positive. On a case by case basis, none of the processes can systematically detect the simulated errors.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    1
    References
    0
    Citations
    NaN
    KQI
    []