Multi-institutional retrospective analysis of learning curves on dosimetry and operation time before and after introduction of intraoperatively built custom-linked seeds in prostate brachytherapy

2016 
This multi-institutional retrospective analysis examined learning curves for dosimetric parameters and operation time after introduction of intraoperatively built custom-linked (IBCL) seeds. Data from consecutive patients treated with seed implantation before and after introduction of IBCL seeds (loose seed, n = 428; IBCL seed, n = 426) were collected from 13 centers. Dose–volume histogram parameters, operation times, and seed migration rates were compared before and after introduction of IBCL seeds. At the 1-month CT analysis, no significant differences were seen in dose to 90% of prostate volume between before and after IBCL seed introduction. No learning curve for dosimetry was seen. Prostate and rectal volume receiving at least 150% of prescription dose (V150 and RV150) were higher in the loose-seed group than in the IBCL-seed group. Operation time was extended by up to 10 min when IBCL seeds were used, although there was a short learning curve of about five patients. The percentage of patients with seed migration in the IBCL-seed group was one-tenth that in the loose-seed group. Our study revealed no dosimetric demerits, no learning curve for dosimetry, and a slightly extended operation time for IBCL seeds. A significant reduction in the rate of seed migration was identified in the IBCL-seed group.