Comparison of Three Protocols for Tight Glycemic Control in Cardiac Surgery Patients

2009 
OBJECTIVE We performed a randomized trial to compare three insulin-titration protocols for tight glycemic control (TGC) in a surgical intensive care unit: an absolute glucose (Matias) protocol, a relative glucose change (Bath) protocol, and an enhanced model predictive control (eMPC) algorithm. RESEARCH DESIGN AND METHODS A total of 120 consecutive patients after cardiac surgery were randomly assigned to the three protocols with a target glycemia range from 4.4 to 6.1 mmol/l. Intravenous insulin was administered continuously or in combination with insulin boluses (Matias protocol). Blood glucose was measured in 1- to 4-h intervals as requested by the protocols. RESULTS The eMPC algorithm gave the best performance as assessed by time to target (8.8 ± 2.2 vs. 10.9 ± 1.0 vs. 12.3 ± 1.9 h; eMPC vs. Matias vs. Bath, respectively; P P P 8.3 mmol/l (1.3 ± 1.2 vs. 12.8 ± 2.2 vs. 6.5 ± 2.0%; P P P CONCLUSIONS The eMPC algorithm provided the best TGC without increasing the risk of severe hypoglycemia while requiring the fewest glucose measurements. Overall, all protocols were safe and effective in the maintenance of TGC in cardiac surgery patients.